POWER MODULE SETUP SHEET
PLEASE READ CAREFULLY BEFORE INSTALLING
SWITCH #1 DELAY SELECT
OFF - NO DELAY
ON - START AND STOP DELAY SET BY FRONT PANEL CONTROLS
START CONTROL - 0 TO 1 SEC.
STOP CONTROL - 0 TO 0.1 OR 1.0 SEC. (SEE JUMP 9)
SWITCH #2 MACHINE MODE SELECT
OFF - L15 OPERATION
ON - L60 OPERATION
SWITCH #3 CLUTCH / BRAKE DELAY SELECT
[L15] SWITCH #3, W/SWITCH #2 OFF
OFF - 0 mS
ON - 25 mS
[L60] SWITCH #3, W/SWITCH #2 ON
OFF - BLOW-ON
ON - TAMP-ON
SWITCH #4 START SWITCH LOGIC LEVEL SELECT
OFF - FALLING SIGNAL EDGE ACTIVATION
ON - RISING SIGNAL EDGE ACTIVATION
SWITCH #5 STOP SWITCH LOGIC LEVEL SELECT
OFF - FALLING SIGNAL EDGE ACTIVATION
ON - RISING SIGNAL EDGE ACTIVATION
JUMPERS #6 START SWITCH TYPE SELECT
PINS 1 & 2 - SPDT START SWITCH
PINS 2 & 3 - SINGLE POLE INPUT
JUMPERS #8 SINGLE POLE START SWITCH POLARITY SELECT
PINS 1 & 2 - SWITCHES TO POSITIVE +5V TO +24V DC (PNP)
PINS 2 & 3 - SWITCHES TO GROUND (NPN)
JUMPERS #9 STOP DELAY SELECT
PINS 1 & 2 - LONG DELAY 0 TO 1 SEC.
PINS 2 & 3 - SHORT DELAY 0 TO 0.1 SEC.
DEFAULT SETTINGS
L-15 L-60
J3 J1
CODER DWELL
ADJUSTMENT
R17
JUMPERS
SWITCHES
PRINTED CIRCUIT BOARD # OO OOO OO
MONTH / NUMBER / YEAR
R-310 SL-1000
The Universal Power Module is designed to
operate the L15, L20, L30, R310, MP25, L60,
and SL1000 series of label machines. The L15,
L20, L30 and MP25 are set up the same!
The L60, R310 & SL-1000 are different,
SEE DEFAULT SETTINGS.
Coder output is adjusted by (R17) top left board
and operates in all modes. The dwell time is
adjustable from 0 to 0.5 seconds. The next
start signal or product signal will be ignored until
the coder pulse is turned off.
(NOTE) IF YOU HAVE L-60 WITH FRONT & REAR
BOARD,
THE BOARD MUST BE SET UP AS L-15.
Page view 62