Universal R-320 Operator's Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 69
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
28
SECTION
4 TROUBLESHOOTING
No power to entire system:
1. Is the emergency switch on the control enclosure pulled out?
2. Is the main switch on the control enclosure “On”?
3. Do all switches in the control enclosure have continuity? Check
with ohmmeter.
4. Is the main fuse in the control enclosure good? Check with
ohmmeter.
5. Is the master control relay in the control enclosure working?
When main switch is turned “On”, it should engage.
6. Is power at power cord? Check with ohmmeter.
No power to conveyor motor:
1. Is the conveyor switch on the control enclosure “On”?
2. Is the neutrik connector at the end of the motor cord plugged
into the junction box at the bottom of the conveyor?
3. Is the conveyor fuse in the control enclosure good? Check with
ohmmeter.
4. Is there DC voltage to motor? Check with ohmmeter.
No Power to product spacer motor:
1. Is the product spacer switch on the control enclosure “On”?
2. Is the neutrik connector at the end of the motor cord plugged
into the junction box at the bottom of the conveyor?
3. Is the product spacer fuse in the control enclosure good? Check
with ohmmeter.
4. Is there DC voltage to motor? Check with ohmmeter.
No power to turning unit motor:
1. Is the turning unit switch on the control enclosure “On”?
2. Is the neutrik connector at the end of the motor cord plugged
into the junction box at the bottom of the conveyor?
3. Is the turning unit fuse in the control enclosure good? Check
with ohmmeter.
4. Is there DC voltage to motor? Check with ohmmeter.
No power to applier:
1. Is the applier switch on the control enclosure “On”?
2. Is the motor switch on the applier “On”?
3. Is the applicator fuse in the control enclosure good? Check with
ohmmeter.
4. Is the fuse in the applicator good? Check with ohmmeter.
5. Is the neutrik connector at the end of the motor cord plugged
into the junction box at the bottom of the conveyor?
6. Is there DC voltage to motor? Check with ohmmeter.
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 68 69

Comments to this Manuals